Operating Freq |
0.1–60MHz continuous.
|
 |
Rated Power (Continuous) |
For 0.1–30MHz:
5000W at VSWR 1:1
2500W at VSWR 2:1
1600W at VSWR 3:1
For 30–60MHz:
3600W at VSWR 1:1
1800W at VSWR 2:1
1200W at VSWR 3:1
|
 |
Characteristic Impedance |
50 ohms unbalanced; UHF type SO239A PTFE connectors.
|
 |
Mismatch VSWR
| For 0.1–2MHz: better than 1.02:1
Up to 30MHz: better than 1.08:1
Up to 60MHz: better than 1.20:1
|
 |
Crosstalk Isolation
| For 0.1–2MHz: better than –100dB
Up to 30MHz: better than –70dB
Up to 60MHz: better than –66dB
|
 |
Operating Time
| Less than 0.15 seconds, including bounces.
|
 |
Parallel I/O Control
| 4-bit BCD input code (positive or inverted—internally selectable), plus RDY output signal.
Logical "low" input: –1 to +1.25V, 1.2kOhm input.
Logical "high" input: +7.5 to +18V, 1.2kOhm input.
Logical "low" output: 0 to 1V, 15/60mA drive/sink.
Logical "high" output: +20 to +30V, 1.2kOhm output.
|
 |
Power Supply
| +24 to +31V DC, 150mA maximum consumption.
Size and Weight: 160mm diam., 105mm high, 1.9kg.
|
 |
Operating Temperature
| –30 to +60°C
|
 |
Weather Rating
| IP53 (dust and rain).
|
 |
Switching Capacity
| 10 antennas to 1 output.
Self-protected anti-hot switching.
Ready to transmit output signal.
Unused antennas grounded (all antennas when off).
|
 |
Size and Weight
| WxDxH = 178x194x182mm, 2.5kg.
|
Features and Functions
- Monitors "ready to transmit" parallel input signal from antenna
switch and generates "transmit inhibit" output signal to the transceiver
for maximum operating flexibility and anti-hot switching protection.
- Directly compatible with ACOM 2000A automatic HF linear amplifier and
ACOM 2000SW remote antenna switch. Control is compatible with other systems
via inverse BCD output code and RS232 serial input (for a PC or other device).
- Local network capability, compatible with ACOM 2000A automatic HF linear amplifier.
- Antenna number 7-segment LED indicator plus sound alarm.
Technical Specifications
 |
Number of Antennas Selectable |
1 from 10.
|
 |
Input Control
| RS232 +/–12V serial port of ACOM 2000A or PC, simple commands.
|
 |
Output Control
| 4-bit inverted parallel BCD code, 27V/25mA bit levels.
|
 |
Power Supply
| 120/240VAC internally selectable, +/– 10% tolerance, 50–60Hz, 15VA.
|
 |
Operating Temperature Range
| 0 to 50°C.
|
 |
Dimensions
| WxHxD = 131x41x162mm.
|
 |
Weight
| 1.3 kg.
|
|
|
|